What is the fire classification of old GST18 cables from before CPR legislation?
‹ Terug naar overzicht- What is the fire classification of old GST18 cables from before CPR legislation?
Answer: Wieland has certified that the H05VV (PVC) and H05Z1Z1 (LS0H) cables it has delivered in the past comply with fire class Eca.
Given the changes to the Building Decree from 1 June 2020, these were no longer allowed to be used in new installations for the uses listed in the Building Decree.
In view of the changes in the BBL 2024 compared to the 2020 Building Decree, where cables of fire class Eca are in contact with indoor or outdoor air, they may not be used in new construction but also no longer in rebuilding of existing installations.