Are GST18 cables in furniture also covered by CPR and NEN1010?

‹ Terug naar overzicht
Are GST18 cables in furniture also covered by CPR and NEN1010?

Answer:  Yes. NEN1010 Section 713 covers electrical installations in furniture (unless another standard applies to this furniture and the electrical installation in it). The provisions in this section apply to cabling systems in furniture connected to the fixed installation, specifically to pluggable electrical installations as per EN61535, regardless of the method used to connect into the fixed installation. The section focuses specifically on protective measures. Cables must be selected as per NEN1010 and be suitable for external influences.

Open Contact opnemen - locatie_EN
  1. Are GST18 cables in furniture also covered by CPR and NEN1010?
  2. What is the CPR?
  3. What is the fire class or Euro class?
  4. Does the CPR apply to pluggable electrical installations; and the Building Decree? And what about the DoP, Declaration of Performance?
  5. What requirements does the Building Decree set out for cables for each application?
  6. Do pluggable electrical installations comply with the fire class requirements of the CPR and the Building Decree?
  7. Are separate GST and BST connectors also covered by CPR?
  8. What is the difference between smoke classes s1, s1a and s1b?
  9. Do connecting cables to devices have to meet the fire class requirements of the CPR or the Building Decree?
  10. Are separate GST and BST connectors also covered by CPR?
  11. What is the fire classification of old GST18 cables from before CPR legislation?
  12. May Eca cables still be used?