Are GST18 cables in furniture also covered by CPR and NEN1010?
‹ Terug naar overzicht- Are GST18 cables in furniture also covered by CPR and NEN1010?
Answer: Yes. NEN1010 Section 713 covers electrical installations in furniture (unless another standard applies to this furniture and the electrical installation in it). The provisions in this section apply to cabling systems in furniture connected to the fixed installation, and specifically to pluggable electrical installations as per EN61535, regardless of the method used to connect into the fixed installation. The section focuses specifically on protective measures. Cables must be selected as per NEN1010 and be suitable for external influences.